MODEL
| 3314D
|
MAX POWER
| 300W
|
MAX CURRENT
| 10A
|
OPERATION VOLTAGE
| 500V
|
OVER POWER PROTECTION
| 315W
|
OVER CURRENT PROTECTION
| 10.5A
|
OVER VOLTAGE PROTECTION
| 525V
|
OVER TEMP. PROTECTION
| 85℃
|
CC MODE
| RANGE
| 0 – 1A
| 0 - 10A
|
RESOLUTION
| 0.268mA
| 2.66mA
|
ACCURACY
| ± 0.2﹪,OF(SETTING + RANGE)
|
CR MODE
| RANGE
| 50-18.75KΩ
| 2.666-50Ω
|
RESOLUTION
| 0.005mS
| 13.33mΩ
|
ACCURACY
| ± 0.2﹪OF (SETTING + RANGE)
|
CV MODE
| RANGE
| 0 -500V
|
RESOLUTION
| 0.133V
|
ACCURACY
| ± 0.1﹪OF (SETTING + RANGE)
|
CP MODE
| RANGE
| 0 - 300W
|
RESOLUTION
| 0.08W
|
ACCURACY
| ± 0.5 OF (SETTING + RANGE)
|
DYNAMIC OPERATION
| THIGH &TLOW
| 50uSec TO 9.999Sec
|
SLEW RATE
| 0.8-50 mA/uSec
| 8-500 mA/uSec
|
ACCURACY
| ± (10﹪ OF SETTING) ±10uS ± (10﹪ OF SETTING) ±10uS
|
VOLTAGE READBACK(V METER)
| RANGE
| ± 199.99V
| ± 500.0V
|
ESOLUTION
| 0.01V
| 0.1V
|
ACCURACY
| ± 0.05﹪OF (READING + RANGE)
|
CURRENT READBACK(A METER)
| RANGE
| ± 10.00 A
|
RESOLUTION
| 1mA
|
ACCURACY
| 0.2 % OF (READING + RANGE)
|
CURRENT MONITOR OUTPUT
| FULL SCALE 10V (ISOLATED WITH LOAD MODULE)
|
CURRENT PROGRAM INPUT
| FULL SCALE 10V (ISOLATED WITH OTHER LOAD MODULE)
|
PROGRAMMABLE SHORT
| BUILT - IN
|
LOAD ON VOLTAGE
| 0.4 - 100V
|
LOAD OFF VOLTAGE
| 0 -100V
|
MAX. SHORT RESISTANCE
| 0.43Ω
|
MAX.SHORT CURRENT
| 10A
|
WEIGHT
| 3.5Kg
|
SIZE
| 108W x 143H x 405Dmm |