MODEL
| 3311D
|
MAX POWER
| 300W
|
MAX CURRENT
| 60A
|
OPERATION VOLTAGE
| 60V
|
OVER POWER PROTECTION
| 315W
|
OVER CURRENT PROTECTION
| 63A
|
OVER VOLTAGE PROTECTION
| 63V
|
OVER TEMP. PROTECTION
| 85℃
|
CC MODE
| RANGE
| 0 - 6A
| 0 - 60A
|
RESOLUTION
| 1.6mA
| 16mA
|
ACCURACY
| ± 0.2﹪,OF(SETTING + RANGE)
|
CR MODE
| RANGE
| 1-3.75KΩ
| 0.0533-1Ω
|
RESOLUTION
| .266mS
| 0.266m
|
ACCURACY
| ± 0.2﹪ OF (SETTING + RANGE)
|
CV MODE
| RANGE
| 0 - 60V
|
RESOLUTION
| 0.016V
|
ACCURACY
| ± 0.1﹪ OF (SETTING + RANGE)
|
CP MODE
| RANGE
| 0 -300W
|
RESOLUTION
| 0.08W
|
ACCURACY
| ± 0.5 OF (SETTING + RANGE)
|
DYNAMIC OPERATIO N
| THIGH &TLOW
| 50uSec TO 9.999Sec
|
SLEW RATE
| 4-250 mA/uSec
| 40mA-2.5 A/uSec
|
ACCURACY
| ± (10﹪ OF SETTING) ±10uS ± (10﹪ OF SETTING) ±10uS
|
VOLTAGE READBACK(V METER)
| RANGE
| 15.0V
| 60.0V
|
ESOLUTION
| 0.001V
| 0.002V
|
ACCURACY
| ± 0.05﹪OF (READING + RANGE)
|
CURRENT READBACK(A METER)
| RANGE
| 6.0A
| 60A
|
RESOLUTION
| 0.001A
| 0.01A
|
ACCURACY
| 0.2% OF (READING + RANGE)
|
CURRENT MONITOR OUTPUT
| FULL SCALE 10V (ISOLATED WITH LOAD MODULE)
|
CURRENT PROGRAM INPUT
| FULL SCALE 10V (ISOLATED WITH OTHER LOAD MODULE)
|
PROGRAMMABLE SHORT
| BUILT - IN
|
LOAD ON VOLTAGE
| 0.1 - 25V
|
LOAD OFF VOLTAGE
| 0 - 25V
|
MAX. SHORT RESISTANCE
| 0.0057Ω
|
MAX.SHORT CURRENT
| 60A
|
WEIGHT
| 3.5Kg
|
SIZE
| 108W x 143H x 405Dmm |